Medical and food-grade silicones are not just cleaner versions of industrial rubber. They are formulated, cured, tested and documented to meet specific regulatory requirements. Skipping any of those steps can turn a promising product into a recall risk.

Platinum cure vs tin cure

Platinum-cure silicones use a platinum-based catalyst and cure at moderate temperatures without byproducts. They are preferred for medical and food-contact applications because they are purer and less likely to leach residues. Tin-cure silicones use an organotin catalyst, cure at room temperature and are cheaper, but they are generally not suitable for skin contact or food contact.

Biocompatibility testing families

  • ISO 10993 series: the standard framework for evaluating biological risk of medical devices.
  • USP Class VI: a United States Pharmacopeia test for plastics in drug and medical applications.
  • FDA 21 CFR 177.2600: regulation covering rubber articles intended for repeated food contact.

The exact tests depend on contact type and duration. A short-term skin-contact device may need cytotoxicity, sensitization and irritation tests. A long-term implantable device needs a much broader battery.

Food-grade requirements

Food-contact silicone must meet FDA 21 CFR 177.2600 for repeated use, or equivalent state and international rules. Pigments, fillers and additives must also be food-contact compliant. Dishwasher and sterilization durability must be tested because heat and detergent can degrade non-compliant formulations.

Documentation for production

  • Material data sheet with lot number and cure system.
  • Biocompatibility or food-contact test summary.
  • Certificate of conformance for each production lot.
  • Process validation records for molding, post-cure and cleaning.

Cleaning and sterilization

Medical silicone parts must survive the intended cleaning method without degrading, discoloring or losing mechanical properties. Common methods include autoclave, gamma irradiation, ethylene oxide and chemical disinfection. Each can affect pigmentation and surface finish, so we validate the chosen method on production-equivalent samples.

Medical grade silicone menstrual cup developed by LA NPDT
The LEIA menstrual cup, a body contact product molded in medical grade silicone.

Case examples from our work

Our Burple burp catcher uses food-grade silicone chosen for dishwasher safety and soft skin contact. The Dignity & Empowerment nurse-call cover uses medical-grade silicone with glow pigment, validated for cleaning and hospital use.

Standards and documents at a glance

Reference
What it covers
Typical use case
ISO 10993
Biological evaluation of medical devices, including cytotoxicity, sensitization and irritation testing
Devices with patient or skin contact
USP Class VI
Biological reactivity testing of plastics and elastomers
Supplier grade selection for medical parts
FDA 21 CFR 177.2600
Rubber articles intended for repeated food contact
Food-contact silicone parts sold in the US
Platinum cure vs tin cure
Cure chemistry; platinum systems avoid tin catalyst byproducts
Skin, food and medical contact parts

Related reading

See silicone rubber prototyping and manufacturing for process options, Burple for a food-contact baby product, and medical product development for hospital-facing work.

Developing a medical or food-contact silicone product?

Start the validation path

Frequently asked questions

Is all platinum-cure silicone medical grade?

No. Platinum cure is a curing chemistry, not a grade. A platinum-cure silicone still needs biocompatibility testing and proper documentation to be used in a medical device.

Can food-grade silicone be used for medical devices?

Generally no. Food-contact compliance does not replace medical biocompatibility testing. The intended use and contact duration determine the required tests.

How long does material validation take?

Simple cytotoxicity and sensitization screens can take a few weeks. Full ISO 10993 batteries can take several months and may require animal testing or validated alternatives. We plan the test path before tooling so it does not delay launch.

Does LA NPDT manage testing?

We help clients select the right test plan and coordinate with accredited labs. We do not run animal or clinical studies in house, but we prepare samples, documentation and traceability for the lab.

Related articles

All articles

Get in touch

Tell us what this is about

Share a few details about your question, partnership, or idea — a member of the LA NPDT team will reply within one business day.

Optional context

What are you looking to accomplish? (optional)

What do you already have? (optional — tick any)

Your information stays confidential and is never shared.